Level 1 data (velocity point-measurements): Difference between revisions
From Atomix
Line 114: | Line 114: | ||
| TIME | | TIME | ||
|- | |- | ||
| colspan="3" | *Data from concurrent sensors may | | colspan="3" | *Data from concurrent sensors may be optionally included e.g., temperature, dissolved oxygen (e.g., eddy-correlation system) | ||
|} | |} | ||
Revision as of 13:29, 14 December 2021
Page status: Draft | |
---|---|
Author(s): | Cynthia |
Reviewer(s): | |
Comment: |
Dimensions
Short name | Standard name | Dimensions | Description |
---|---|---|---|
TIME | time | time | Units in Days since 1950-01-01T00:00:00Z |
TIME_HPR*** | time_of_heading_pitch_roll | TIME_HPR | Heading, pitch and roll (tilt) sensors measure always at 1Hz for Vector ADV |
N_VEL_COMPONENT | number_of_unique_velocity_instruments | N_VEL_COMPONENT | Maximum of 3 for u,v, w (east,north, up) velocities |
N_VEL_INSTRUMENT | number_of_velocity_component | N_VEL_INSTRUMENT | Required only if storing multiple synchronised instruments in the same file |
Variables
Required variables
Short name | Standard name | Dimensions | Description |
---|---|---|---|
ABSIC | backscatter_intensity_from_acoustic_beam | TIME, N_VEL_COMPONENT, N_VEL_INSTRUMENT | |
CORRN | noise_correlation_percent_from_each_acoustic_beam | TIME, N_VEL_COMPONENT, N_VEL_INSTRUMENT | |
XYZ_VEL* (or ENU_VEL/BEAM_VEL) | TIME, N_VEL_COMPONENT, N_VEL_INSTRUMENT | ||
HEIGHT or DEPTH variable[math]\displaystyle{ \dagger }[/math] | TIME, N_VEL_INSTRUMENT | ||
HEADING | TIME_HPR, N_VEL_INSTRUMENT | ||
PITCH | TIME_HPR, N_VEL_INSTRUMENT | ||
ROLL | TIME_HPR, N_VEL_INSTRUMENT | ||
* Some manufacturers record quality-control variables (e.g., CORRN) in the instrument coordinate system. For example, Nortek records these variables in the instrument XYZ frame of reference. It's best to record the data in that coordinate system.
[math]\displaystyle{ \dagger }[/math] A variable situating the instruments in the water column is required. This may be a nominal depth/height or a time-varying depth or height above the bottom. |
Optional variables
Short name | Standard name | Dimensions |
---|---|---|
PRES | TIME, N_VEL_INSTRUMENT | |
SNR | TIME, N_VEL_COMPONENT | |
TEMP, and other scalars* | TIME | |
*Data from concurrent sensors may be optionally included e.g., temperature, dissolved oxygen (e.g., eddy-correlation system) |
Group attributes (metadata)
This section describes attributes that may provide additional information about how the data was processed and manipulated at this stage.
Required metadata
- Att 1
- Att2
Optional metadata
- Enter here