Level 1 data (shear probes): Difference between revisions
No edit summary |
No edit summary |
||
Line 7: | Line 7: | ||
=Dimensions= | =Dimensions= | ||
<div class="mw-collapsible | <div class="mw-collapsible mw-collapsed" data-collapsetext="Collapse" data-expandtext="Expand"> | ||
<br> | |||
{| class="wikitable sortable" | {| class="wikitable sortable" | ||
Line 29: | Line 30: | ||
|- | |- | ||
|} | |} | ||
<br> | |||
<math>^a</math> Typically we assume TIME for the fast-sampled microstructure channels, and eventually _SLOW or _CTD for slower sampled channels such as CTD and tilt sensors. If the application requires different time stamps for different sensors, this can be utilized like TIME_PITCH, TIME_ACC etc. | <math>^a</math> Typically we assume TIME for the fast-sampled microstructure channels, and eventually _SLOW or _CTD for slower sampled channels such as CTD and tilt sensors. If the application requires different time stamps for different sensors, this can be utilized like TIME_PITCH, TIME_ACC etc. | ||
</div> | </div> | ||
=Required Variables= | =Required Variables= | ||
<div class="mw-collapsible | <div class="mw-collapsible mw-collapsed" data-collapsetext="Collapse" data-expandtext="Expand"> | ||
<br> | |||
{| class="wikitable sortable" | {| class="wikitable sortable" | ||
Line 46: | Line 49: | ||
=Optional Level 1 Variables= | =Optional Level 1 Variables= | ||
<div class="mw-collapsible | <div class="mw-collapsible mw-collapsed" data-collapsetext="Collapse" data-expandtext="Expand"> | ||
<br> | |||
{| class="wikitable sortable" | {| class="wikitable sortable" | ||
Line 70: | Line 74: | ||
| ROLL || platform_roll_angle || degree || TIME <math>^a</math> | | ROLL || platform_roll_angle || degree || TIME <math>^a</math> | ||
|} | |} | ||
<br><math>^a</math> or TIME_SLOW or TIME_CTD | |||
<br><math>^b</math> or TIME_SLOW | |||
</div> | </div> | ||
------ | ------ |
Revision as of 11:19, 7 May 2022
Level 1 data refers to the full resolution data in physical units, e.g. the regularly sampled time series of converted shear probe data. If needed, a transfer function for shear is given. Below, a table with parameters included in the level 1 data set is compiled. The parameter names and definitions fit the NetCDF parameter attributes.
In the standard names, "sea_water" can be replaced with "water" if working in freshwater environments. This is specified in some entries below but not all.
Dimensions
Dimension short name | description |
---|---|
TIME | Time axis for the microstructure sampling rate |
TIME_CTD | Time axis for the CTD sampling rate. |
TIME_*** [math]\displaystyle{ ^a }[/math] | Time axis for the *** sensor sampling rate |
N_SHEAR_SENSORS | number of shear channel |
N_***_SENSORS | number of *** channel (e.g., N_VIB_SENSORS, N_ACC_SENSORS) |
[math]\displaystyle{ ^a }[/math] Typically we assume TIME for the fast-sampled microstructure channels, and eventually _SLOW or _CTD for slower sampled channels such as CTD and tilt sensors. If the application requires different time stamps for different sensors, this can be utilized like TIME_PITCH, TIME_ACC etc.
Required Variables
Parameter Name | Standard Name | Units of measurement | dimension |
---|---|---|---|
TIME | time | Days since YYYY-MM-DDT00:00:00Z | TIME |
SHEAR | sea_water_velocity_shear (or water_velocity_shear) |
s-1 | [TIME, N_SHEAR_SENSORS] |
Optional Level 1 Variables
Parameter Name | Standard Name | Units of measurement | dimension |
---|---|---|---|
PSPD_REL | platform_speed_wrt_sea_water | m s-1 | TIME [math]\displaystyle{ ^a }[/math] |
VIB | platform_vibration | NA | [TIME, N_VIB_SENSORS] |
ACC | platform_acceleration | m s-2 | [TIME [math]\displaystyle{ ^b }[/math], N_ACC_SENSORS] |
TEMP | sea_water_temperature (water_temperature) |
degree_Celsius | [TIME_CTD [math]\displaystyle{ ^b }[/math], N_T_SENSORS] |
CNCD | sea_water_electrical_conductivity (water_electrical_conductivity) |
S m-1 | [TIME_CTD [math]\displaystyle{ ^b }[/math], N_C_SENSORS] |
GRADT | temperature_gradient | [TIME, N_GRADT_SENSORS] | |
GRADC | conductivity_gradient | [TIME, N_GRADC_SENSORS] | |
PITCH | platform_pitch_angle | degree | TIME [math]\displaystyle{ ^a }[/math] |
ROLL | platform_roll_angle | degree | TIME [math]\displaystyle{ ^a }[/math] |
[math]\displaystyle{ ^a }[/math] or TIME_SLOW or TIME_CTD
[math]\displaystyle{ ^b }[/math] or TIME_SLOW
return to Dataset requirements for shear probes.