Level 2 data(shear probes)

Level 2 data are the full resolution, cleaned and despiked parameter from level 1. The initial data set is subdivided in sections and labelled accordingly in the parameter SECTION_NUMBER with integers. Level 2 data is ready for estimating spectra, which will be corrected in wavenumber/frequency domain for the spatial averaging of the shear probe and for vibration-coherent content. In addition to cleaned and despiked level 1 data channels, level 2 data comprises the additional parameter summarized in the table below.

Numbers in the last column indicate:

required=1 are the absolute minimum parameter required for a data set
required=2 are preferred/recommended parameter
required=3 are optional parameter
Parameter Name CF parameter Standard name Units of measurement dimension required
SECTION_NUMBER 0 dimensionless [TIME_FAST] 1
FLOWPS 0 flow_past_sensor m s-1 [TIME_FAST, n_shear_sensors] 1
PSAL 1
(0)
sea_water_practical_salinity
water_practical_salinity
dimensionless TIME_FAST 2
SIG0 1
(0)
sea_water_sigma_theta
water_sigma_theta
kg m-3 TIME_FAST 2