== Quality Control of Dissipation Estimates ==
- Reject ensembles where the slope is negative (i.e. εi<0)
- Reject ensemble where Ni values are unreasonable (I.e. NSubscript texti<0).
- Estimate the uncertainty in εi as the 95% confidence interval on the slope. Reject values that are too large (e.g. delta εi / εi >0.6).
- Average the εi estimates from the diverging beams (if applicable) to determine ε.
- Check if distribution of ε is lognormal