Wavenumber response of the shear probe

From Atomix
Revision as of 16:08, 5 October 2021 by Aleboyer (talk | contribs)

The probe-response correction depends on the dimensions of the shear probe. For a commonly used shear probe the spectrum is corrected for the spatial averaging of the shear probe by multiplying it by the factor correction 1+(kk0)2 where k0 = 50 cpm and k is the wavenumber expressed in units of cpm [1]. The correction reaches a factor of 10 at a wavenumber of 150 cpm, and it is not recommended to use spectral data beyond this wavenumber unless the probe is small and k0 is larger than 50 cpm.

References

  1. ↑ Macoun, P., & Lueck, R. (2004). Modeling the spatial response of the airfoil shear probe using different sized probes. Journal of Atmospheric and Oceanic Technology, 21(2), 284-297.