Shear probes quality control metrics

From Atomix
Revision as of 11:57, 15 November 2021 by Marcus (talk | contribs)

Spikes in epsilon estimates arise from a number of causes such as collisions of sensor tips with suspended particles (e.g. detritus, plankton, jelly fish, seaweed), electronic noise due to other sensors, or mechanical platform vibrations. This section describes quality control measures and its coding.

In a first step, epsilon estimates are flagged based on quality control metric and disagreement between dissipation estimates from redundant sensors.

  1. Quality-control metrics that accompanied dissipation estimates are used to flag individual estimates. In particular, quality control thresholds for
  2. Agreement between dissipation estimates from redundant sensors (i.e. two or more shear probes) does not exist.

Flagged data will receive quality control coding 4.

In a second step of quality control, a review of ensembles that have been flagged is performed. Individual shear spectra, associated tilt and acceleration data and microstructure thermistor data/spectra are visually examined for consistency. Previously flagged data that appears to be good data will receive quality control coding 2.

Details for QC coding can be found here.




return to Flow chart for shear probes