Quality control coding
From Atomix
[In progress]
Shear-probe quality-control flags
The Q (quality control) flags associated with shear-probe measurements are bitwise flags with boolean values which are CF compliant. More information available here: https://mplnet.gsfc.nasa.gov/about-flags
Every dissipation estimate from every probe must have Q flag. The numerical values of the Q flags are as follows:
Flag Mask | Bit | Flag Meaning | Example threshold value | Ex: True =1 / False =0 | Ex: Q value |
---|---|---|---|---|---|
1 | Bit 0 | Poor figure of merit | 2 | 0 | 0 |
2 | Bit 1 | Large fraction of data with spikes | 40% | 0 | 0 |
4 | Bit 2 | Anomalously large disagreement between dissipation estimates from probes | N/A | 1 | 4 |
8 | Bit 3 | Too many iterations of despiking routine | To be confirmed | 0 | 0 |
16 | Bit 4 | Insufficient variance resolved | 50% | 1 | 16 |
32 | Bit 5 | manual flag to be defined by user | N/A | 0 | 0 |
64 | Bit 6 | manual flag to be defined by user | N/A | 0 | 0 |
128 | Bit 7 | manual flag to be defined by user | N/A | 0 | 0 |
Final Q = 20 |
The Q flags are combined by their addition. For example a Q value of 20 means that the dissipation estimated failed both dissipation ratio limit test and the resolved variance test. A value of 255 means that all tests failed. The reasons for a failure can be decoded by breaking the value of Q down to its powers of 2.
return to Flow chart for shear probes