<div class="mw-collapsible mw-collapsed" id=" | <div class="mw-collapsible mw-collapsed" id="env" data-collapsetext="Collapse" data-expandtext="Expand conditions"> | ||
#* Ensure measurement velocity range is sufficient for anticipated background flow, tides, surface waves and internal waves | #* Ensure measurement velocity range is sufficient for anticipated background flow, tides, surface waves and internal waves | ||
#* For pulse-pulse coherent measurements, minimize potential issues due to phase wrapping by setting the ambiguity velocity to be larger than the maximum flow speed that is expected | #* For pulse-pulse coherent measurements, minimize potential issues due to phase wrapping by setting the ambiguity velocity to be larger than the maximum flow speed that is expected | ||
Line 9: | Line 9: | ||
= Velocity Measurements = | = Velocity Measurements = | ||
<div class="mw-collapsible mw-collapsed" id=" | <div class="mw-collapsible mw-collapsed" id="vel" data-collapsetext="Collapse" data-expandtext="Expand measurements"> | ||
#* Record raw data in along-beam coordinates | #* Record raw data in along-beam coordinates | ||
#* Maximise velocity accuracy whilst minimising averaging (pings per ensemble) | #* Maximise velocity accuracy whilst minimising averaging (pings per ensemble) | ||
Line 19: | Line 19: | ||
= Motion control during deployment = | = Motion control during deployment = | ||
<div class="mw-collapsible mw-collapsed" id=" | <div class="mw-collapsible mw-collapsed" id="motioncontrol" data-collapsetext="Collapse" data-expandtext="Expand motion control"> | ||
#* For bottom mounted instruments, minimise motion by ensuring that the frame is sufficiently heavy and streamlined to withstand the flow conditions at the deployment location | #* For bottom mounted instruments, minimise motion by ensuring that the frame is sufficiently heavy and streamlined to withstand the flow conditions at the deployment location | ||
#* For moored instruments, minimise motion by ensuring there is sufficient buoyancy on frame to hold position well. Also ensure that the buoyancy components do not obstruct beam path | #* For moored instruments, minimise motion by ensuring there is sufficient buoyancy on frame to hold position well. Also ensure that the buoyancy components do not obstruct beam path | ||
Line 27: | Line 27: | ||
= Power and Storage for self-contained deployments = | = Power and Storage for self-contained deployments = | ||
<div class="mw-collapsible mw-collapsed" id=" | <div class="mw-collapsible mw-collapsed" id="power-storage" data-collapsetext="Collapse" data-expandtext="Expand power and storage"> | ||
#* Ensure the battery and memory capacity are sufficient for the planned deployment duration | #* Ensure the battery and memory capacity are sufficient for the planned deployment duration | ||
#* Factor in the expected water temperature when estimating the battery capacity and energy consumption | #* Factor in the expected water temperature when estimating the battery capacity and energy consumption |
Revision as of 16:38, 15 November 2021
In order to collect useful measurements that actually resolve the turbulence statistics consistent with the application of the Kolmogorov hypotheses of isotropic turbulence, it is important to configure and deploy your instrument using best practices. In setting up your instrument, it is recommended that consider the following recommendations:
Environmental Conditions
Velocity Measurements
Motion control during deployment
Power and Storage for self-contained deployments
Next Step: Raw data review (QA1)
Return to ADCP Flow Chart front page